The Throughbolt Anchor, also known as the can-through bolt, is a bolt that expands tightening of the nut on a taper stud. These bolts are usually Zinc Plated either in White or Yellow or Stainless Steel 304Gr and come in a variety of diameters and lengths
Selection of the right length?
This is quite simple. We add the thickness of the material that needs to be fastened, the minimum embedment and the thickness of the nut and washer.
How do I space my anchors?
The material (usually concrete) in which the Strike Anchors are installed are subjected to forces by the anchors. Installation of these anchors, too close to each other, can cause these forces to interact and consequently lowering the holding power of the anchors. As a thumb rule, the concrete anchor industry has established a minimum standard of ten (10) anchor diameters for spacing between anchors and five (5) anchor diameters from an unsupported edge. When vibration or sudden impact are part of the load condition, spacing between anchors should be increased.
How to install a Throughbolt Anchor Fastener?
Technical Specifications
Measure | UoM | M6 | M8 | M10 | M12 | M16 | M20 | M24 |
Thread Diameter | mm | 6 | 8 | 10 | 12 | 16 | 20 | 24 |
Drill Hole Diameter | mm | 6 | 8 | 10 | 12 | 16 | 20 | 24 |
Clearance Hole Diameter | mm | 7 | 9 | 12 | 14 | 18 | 22 | 26 |
Embedment depth | mm | 35 | 40 | 50 | 60 | 70 | 100 | 120 |
Min.structure Thickness | mm | 50 | 60 | 80 | 100 | 110 | 130 | 180 |
Ultimate Tensile Strength | N/mm² | 500 | 500 | 500 | 500 | 400 | 400 | 400 |
Yield Strength | N/mm² | 400 | 400 | 400 | 400 | 240 | 240 | 240 |
Rec.Tightening Torque | Nm | 6 | 10 | 28 | 34 | 85 | 160 | 300 |
Characteristic Tensile Load | kN | 5.4 | 8.4 | 12.9 | 20.4 | 24 | 32.4 | 57.6 |
Recommended Tensile Load | kN | 1.8 | 2.8 | 4.3 | 6.8 | 8 | 10.8 | 26.2 |
Characteristic Shear Load | kN | 5.8 | 8 | 14.5 | 18 | 26 | 35 | 74 |
Recommended Shear Load | kN | 2.3 | 3.2 | 5.8 | 7.2 | 10.4 | 14 | 49.3 |
Minimum Centre Spacing | mm | 70 | 80 | 100 | 120 | 140 | 200 | 240 |
Minimum Edge Distance | mm | 50 | 60 | 80 | 100 | 130 | 160 | 200 |
Normal Embedment
Loads Stated are for 30 N/mm² concrete (C20/25)
Shear loads are away from a free edge
Ultimate Tensile Strength specified from the grade of material 5.8 and 4.6.
Yield Strength a multiplication of the grade factor x
Ultimate tensile Strength (eg 5.8 = 500 x .8 = 400)
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Nulla nibh magna, sollicitudin eget erat condimentum, mollis mattis justo. Vestibulum auctor elementum enim quis sagittis. Cras elementum nisl